| Liang Chi Pep Water Filter System |
 |
| • Fiberglass vessel with PVC piping • Flows from 43 to 241 GPM (per vessel) • Single and multiple vessel systems • Operating pressure up to 50 psig
Features: • Stainless steel base plate for long life • Oversized 600 in-lb. torque actuator • NEMA 4X UL listed control panel with clear cover • Metal Pumps – longer life
SMF series media filters are uniquely designed removing suspended solids from water and fluid systems. Using specialized permanent media, solids are removed to a level of 0.5 micron. As solids are removed, the pressure drop across the media will increase. The unit will automatically backwash to self-clean the media based upon pressure drop or time |
| |
| |
| Magnetic water conditioner |
|  |
| Internal Magnetism Type | more | pdf format 955KB |
| | |
 |  |
 |  |
 |  |
|
| |
|
|  |
| Before use | After use |
| |
| New Technology on Anti-scale - Saving in water, chemical & energy, No operation cost |
| Water cooling system is commonly used in non-residential buildings and areas with high cooling demand because the use of water cooled chiller plant can achieve almost 20% energy saving rather than air cooled chiller plant in Central Air-Conditioning Plant (A/C plant). Hong Kong SAR Government broadly promotes the use of water cooling system and allowing all new buildings or non-residential buildings in specified districts using natural water supplies in water cooling process. Scale deposit (mainly calcium carbonate) will be built up in the process of water cooling system which results in lowering the efficiency and effectiveness of heat transfer and increase in energy consumption. Even a scale film as thin as 0.2mm, energy consumed will be increased by 7 %. At the time being, traditional chemical methods have been used to remove scale deposit which results in expensive chemical cost and huge water wastage. For a small commercial complex with A/C cooling capacity of 3,000RT (Refrigeration Ton), the annual expenditure on chemical treatment will be up to $640,000 ($370,000 for water bleeding-off and $270,000 for chemical cost). Moreover, this method will critically pollute the environment by water wastage. | more | pdf format 279KB |
| |
| Electronic Water Treatment |
   |
| Randomly varying electric fields are induced into the water. These fields propagate through the water in the entire plumbing system. The result is the production of nuclei everywhere in water system. When the water is heated, the resulting precipitate that usually deposits on the surfaces, grows in suspension and develops as a crystal on the nuclei and is then washed away in the flow. The fields treat the water both up and down stream and is transmitted into the central heating system to treat the primary water. The treated water is normally able to dissolve existing scale in just a few weeks. |
| |
| Water Cooling Tower Ozonator |
 |
| - Cooling towerozonator inhibits corrosion, scale, fouling, and slime effectively without adding any chemicals. |
| - Ozone will naturally decay with 20 minutes so here is no concern for chemical residuals. |
| - Utilize a cooling tower ozonator will reduce water, energy consumption and maintenance cost of cooling tower. |